CB MEXICO 2023 GC | ||||||
Emergency broadcast is requested by Movistar MEXICO in a regulated standard named CBMexico. The implementation of this standar is MANDATORY to get approval. | ||||||
RULE 1: | ||||||
The title of the message must change depending on the channel. (check complete table) | ||||||
Function | Primary channels: | Title of the messages. | Can be turned OFF | |||
Level 1 | 4370, 4383 | Mensajes de Alerta presidencial | NO | |||
Level 2 | 4371, 4372 , 4384, 4385 | Mensajes de Alerta extrema | YES | |||
Level 3 | 4373,4374, 4375, 4376, 4377, 4378, 4386,4387,4388,4389,4390, 4391 | Mensajes de Alerta grave | YES | |||
Amber Alert | 4379 | Mensajes de Alerta Amber | YES | |||
Testing Channels | 4380 | Mensajes de Alerta de Prueba | YES | Special channel Check rule no. 8. | ||
Simulation channels | 4381 | Mensajes de Alerta de Ejercicio | YES | |||
Information | 6400 | Mensajes de información | YES | |||
Reserved channels | 4396,4397,4398, 4399 | Canal Reservado | YES | |||
RULE 2: | ||||||
The message sound and vibration must reproduce for EXACLTY 8 Seconds. It must stop automatic after 8 seconds. | ||||||
RULE 3: | ||||||
Limit the message body to be able to show only 82 characters. | ||||||
RULE 4: | ||||||
The Cell broadcast messages should arrive in all audio profiles. (Normal, Vibration, Silent, etc) Always with audible and vibration. | ||||||
RULE 5: | ||||||
All languages must be active by default, the user must not be able to turn off. | ||||||
RULE 6: | ||||||
All Cell broadcast messages should have DATE AND TIME. | ||||||
RULE 7: | ||||||
Default language must be SPANISH. | ||||||
RULE 8: | ||||||
TURN ON: The channel 4380 must be turned ON using the USSD Code *#*#202304*#*# | ||||||
TURN OFF: The channel 4380 must be turned OFF using the USSD Code *#*#202404*#*# | ||||||
<!-- Whether to display state/local test settings, some countries/carriers want to enable it by default and not allow users to disable -->
<bool name="show_state_local_test_settings">true</bool>
<!-- Whether to display exercise test settings when testing mode is off. -->
- <bool name="show_exercise_settings">false</bool>
+ <bool name="show_exercise_settings">true</bool>
<!-- whether to display a separate exercise test settings. today, most of time, exercise channels was controlled by the main test toggle. -->
- <bool name="show_separate_exercise_settings">false</bool>
+ <bool name="show_separate_exercise_settings">true</bool>
<!-- Whether to display operator defined test settings when testing mode is off. -->
<!-- This is read only when show_separate_exercise_settings is on -->
<bool name="show_operator_defined_settings">false</bool>
@@ -94,7 +94,7 @@
<!-- Other test alerts toggle default value -->
<bool name="test_alerts_enabled_default">true</bool>
<!-- Exercise test alerts toggle default value -->
- <bool name="test_exercise_alerts_enabled_default">false</bool>
+ <bool name="test_exercise_alerts_enabled_default">true</bool>
<!-- Operator defined test alerts toggle default value -->
<bool name="test_operator_defined_alerts_enabled_default">false</bool>
文章来源:https://www.toymoban.com/news/detail-420428.html
<resources>
<!-- Channel 4370, 4383 -->
<string-array name="cmas_presidential_alerts_channels_range_strings" translatable="false">
- <item>0x1112:rat=gsm, emergency=true, alert_duration=86400000, always_on=true</item>
- <item>0x111F:rat=gsm, emergency=true, alert_duration=86400000, always_on=true</item>
+ <item>0x1112:rat=gsm, emergency=true, alert_duration=8200, always_on=true</item>
+ <item>0x111F:rat=gsm, emergency=true, alert_duration=8200, always_on=true</item>
</string-array>
- <!-- Channel 50, 919, and 4396-4399 -->
+ <!-- 4371,4372, 4384, 4385 -->
+ <string-array name="emergency_alerts_channels_range_strings" translatable="false">
+ <item>0x1113:rat=gsm, emergency=true, override_dnd=true, alert_duration=8200</item>
+ <item>0x1114:rat=gsm, emergency=true, override_dnd=true, alert_duration=8200</item>
+ <item>0x1120:rat=gsm, emergency=true, override_dnd=true, alert_duration=8200</item>
+ <item>0x1121:rat=gsm, emergency=true, override_dnd=true, alert_duration=8200</item>
+ </string-array>
+
+ <!-- 4373~4378, 4386~4391 -->
+ <string-array name="cmas_alerts_severe_range_strings" translatable="false">
+ <item>0x1115-0x111A:rat=gsm, emergency=true, override_dnd=true, alert_duration=8200</item>
+ <item>0x1122-0x1127:rat=gsm, emergency=true, override_dnd=true, alert_duration=8200</item>
+ </string-array>
+
+ <!-- 4379 -->
+ <string-array name="cmas_amber_alerts_channels_range_strings" translatable="false">
+ <item>0x111B:rat=gsm, emergency=true, override_dnd=true, alert_duration=8200</item>
+ </string-array>
+
+ <!-- Channel 4396-4399 -->
<string-array name="additional_cbs_channels_strings" translatable="false">
- <item>0x397:rat=gsm, emergency=true, alert_duration=86400000, always_on=true</item>
- <!-- Channel 50 for area update info -->
- <item>0x032:type=area, emergency=false, alert_duration=86400000, always_on=true</item>
<!-- Channel 4396-4399 reserved for future -->
- <item>0x112C-0x112F:rat=gsm, emergency=true, alert_duration=86400000, always_on=true</item>
+ <item>0x112C-0x112F:rat=gsm, emergency=true, alert_duration=8200</item>
</string-array>
- <!-- Channel Test 4380 519 -->
+ <!-- Channel Test 4380-->
<string-array name="required_monthly_test_range_strings" translatable="false">
- <item>0x111C:rat=gsm, emergency=true, alert_duration=86400000, always_on=true</item>
- <item>0x0207:rat=gsm, emergency=true, alert_duration=86400000, always_on=true</item>
+ <item>0x111C:rat=gsm, emergency=true, alert_duration=8200</item>
</string-array>
<!-- Channel Test 4381 -->
<string-array name="exercise_alert_range_strings" translatable="false">
- <item>0x111D:rat=gsm, emergency=true, alert_duration=86400000, always_on=true</item>
+ <item>0x111D:rat=gsm, emergency=true, alert_duration=8200</item>
</string-array>
<!-- Channel Test 4382 -->
<string-array name="operator_defined_alert_range_strings" translatable="false">
- <item>0x111E:rat=gsm, emergency=true, alert_duration=86400000, always_on=true</item>
+ <item>0x111E:rat=gsm, emergency=true, alert_duration=8200</item>
+ </string-array>
+
+ <!-- Channel 6400 -->
+ <string-array name="public_safety_messages_channels_range_strings" translatable="false">
+ <item>0x1900:rat=gsm, emergency=true, type=info, alert_duration=8200</item>
</string-array>
<!-- Play alert sound in full volume regardless Do Not Disturb is on -->
@@ -37,12 +57,6 @@
<!-- Link method -->
<string name="link_method" translatable="false">none</string>
- <!-- Show area update info settings in CellBroadcastReceiver and information in SIM status in Settings app -->
- <bool name="config_showAreaUpdateInfoSettings">true</bool>
-
- <!-- Other test alerts toggle default value -->
- <bool name="test_alerts_enabled_default">true</bool>
-
<!-- whether to display a separate operator defined test settings. today, most of time, operator defined channels was controlled by the main test toggle. -->
<bool name="show_separate_operator_defined_settings">true</bool>
@@ -52,7 +66,26 @@
<!-- Whether to disable cell broadcast severe alert when extreme alert is disabled -->
<bool name="disable_severe_when_extreme_disabled">false</bool>
- <string name="date_time_format" translatable="false">"yyyy-MM-dd, HH:mm a"</string>
+ <bool name="show_severe_alert_settings">true</bool>
+ <bool name="severe_threat_alerts_enabled_default">true</bool>
+
+ <bool name="show_amber_alert_settings">true</bool>
+ <bool name="amber_alerts_enabled_default">true</bool>
+
+ <bool name="show_separate_exercise_settings">true</bool>
+ <bool name="show_exercise_settings">true</bool>
+ <bool name="test_exercise_alerts_enabled_default">true</bool>
+
+ <bool name="public_safety_messages_enabled_default">true</bool>
+ <bool name="show_public_safety_settings">true</bool>
+
+ <bool name="override_dnd_default">true</bool>
+
+ <bool name="test_alerts_enabled_default">true</bool>
+ <bool name="show_test_settings">false</bool>
+ <bool name="allow_testing_mode_on_user_build">true</bool>
+
+ <string name="date_time_format" translatable="false">"yyyy-MM-dd, hh:mm a"</string>
<integer name="alert_message_count_limit">82</integer>
</resources>文章来源地址https://www.toymoban.com/news/detail-420428.html