一次上架锐捷交换机,由于ODF光衰不稳定,导致交换机端口down,排查很多发现以下故障:
重置18000-X端口发现提示一下命令:
Port in violation! Use ‘errdisable recovery’ command to up the port!
gz-sprine1#show interfaces tenGigabitEthernet 4/5 status
Interface Status Vlan Duplex Speed Type
TenGigabitEthernet 4/5 disabled routed Unknown Unknown fiber
修改 err为30s: errdisable recovery interval 30
恢复出错的端口:errdisable recovery cause link-state
重新检查交换机的状态,恢复正常。
gz-sprine1#show interfaces tenGigabitEthernet 4/5 st
gz-sprine1#show interfaces tenGigabitEthernet 4/5 status
Interface Status Vlan Duplex Speed Type
TenGigabitEthernet 4/5 down routed Unknown Unknown fiber
gz-sprine1#文章来源:https://www.toymoban.com/news/detail-621574.html
备注:端口处于error状态,端口不会发光,技术上称为假死。文章来源地址https://www.toymoban.com/news/detail-621574.html
到了这里,关于锐捷18000-X端口假死现象的文章就介绍完了。如果您还想了解更多内容,请在右上角搜索TOY模板网以前的文章或继续浏览下面的相关文章,希望大家以后多多支持TOY模板网!